Components

G10 Isolating Sleeves

The standard industrial sleeve

G10 is a glass fabric reinforced epoxy laminate, and it is the sleeve material Protek supplies as standard for industrial isolation. A G10 sleeve is machined to the bolt diameter with a wall that clears the flange bolt hole, so the stud runs on a hard, dimensionally stable insulating tube rather than on a film that can wrinkle during fit-up.

The properties that matter for a sleeve are dielectric strength and moisture pick-up. G10 has high dielectric strength in the dry condition and absorbs very little water compared with paper-based laminates or nylon, so its electrical performance does not drift on a joint that spends its life outdoors, buried or in a humid plant. It is also mechanically strong enough that it does not deform when a stud is pushed through at an angle during assembly.

G10 sleeves are used in the PS-300 standard industrial set and the PS-400FS fire-safe set, and they are normally paired with G10 isolating washers and zinc-plated or hardened coated steel backing washers. Because the retainer in a Delta gasket is also G10, a Delta joint often carries the same material in three places, which keeps specification and spares simple.

Typical properties

Typical properties of G10 glass-epoxy
StandardNEMA G10 / MIL-I-24768/2
Dielectric strength (typical)800 V/mil — short-time, Condition A
Compressive strength (typical)65,000 psi
Temperature284°F (140°C)
Water absorption≤0.25%
NotesThe standard dielectric retainer: high compressive strength, low moisture pick-up, good electrical strength in the dry condition.

Typical values for comparison, not specifications. Actual properties vary by manufacturer, thickness, construction and test method.

Sizing

  • Inside diameter sized from the bolt diameter with running clearance.
  • Wall thickness approximately 0.031" for a G10 sleeve.
  • Outside diameter checked against the flange bolt hole before release.
  • Length follows the distance between the isolating washers, through both flanges and the gasket.

Confirm the bolt hole diameter for the flange class in the flange dimensions tool.

Flange dimensions tool

Where it is used

PS-300 Standard Industrial

G10 sleeve, G10 isolating washer, zinc-plated steel washer — the general duty set.

View page

PS-400FS Fire Safe

G10 sleeve with G10 isolating washers and hardened coated steel washers for fire-safe kits.

View page

PROTEK DELTA and RANGER

The usual sleeve in industrial Delta and Ranger kits.

View page

Sizes and how to order

Sizes available

1/2" to 24" ASME B16.5 bolting. Larger and specialty sizes on request.

How to order

Order a G10 sleeve as an individual component, in a PS-300 or PS-400FS set, or as part of a complete isolation kit sized to the flange.

Chemical compatibility snapshot

Ratings at ambient temperature from the chemical compatibility matrix, which covers 44 media. A snapshot is shown here — open the tool for the full matrix and the service temperature notes.

G10

Holds up against

Water, fresh/cooling · Seawater / brine · Produced water (H2S/CO2/chlorides) · Crude oil, sweet · Crude oil, sour (H2S)

Limited or not recommended

Steam (to 300°F) · Hydrochloric acid, concentrated · Sulfuric acid, concentrated (93–98%) (not recommended) · Nitric acid, dilute (<10%) · Nitric acid, concentrated (not recommended)

Full chemical compatibility matrix
FAQ

Frequently asked questions

What is a G10 isolating sleeve made of?

+

A glass fabric reinforced epoxy laminate to NEMA G10 / MIL-I-24768/2, machined to the bolt and hole diameter of the flange.

Is G10 better than Mylar for a sleeve?

+

G10 is stronger and more dimensionally stable, and it behaves better in wet service. Mylar has higher dielectric strength per unit thickness and is the more economical choice for moderate-temperature work.

What temperature can a G10 sleeve take?

+

Typical G10 service is around 284°F (140°C). Above that, Protek uses Nomex sleeves in the PS-500HT high-temperature set.

Does a G10 sleeve need a matching washer?

+

The set is normally matched: PS-300 and PS-400FS pair a G10 sleeve with G10 isolating washers so the whole stack has the same dielectric and temperature behaviour.

Ready to specify?

Configure the kit for your flange

Build the gasket, sleeve and washer set for your flange and download the drawing and bill of materials, or send the service conditions to Protek Engineering for a written recommendation.