High Pressure Isolation Gaskets
Class 900 to 2500 and API 10K to 15K
Above ANSI Class 900 the joint stops being forgiving. Bolt loads are high, the gasket area is small, and the isolating elements have to carry that load without creeping, cracking or losing the electrical break. Protek covers this range with two constructions: Ranger, a 316 stainless steel core with a mechanically retained PTFE spring-energized seal, and Ranger FS, the same class of duty with a fire-safe isolation gasket certified to API 6FB Third Edition. Both are available from 1/2" to 48", ANSI 150–2500 and API 2K–15K, up to 392°F (200°C).
Sizing is the part that decides whether a high class isolation joint works. The isolating washer has to spread the bolt load without crushing, the sleeve has to clear the bolt hole without becoming the load path, and the backing washer has to take the nut bearing stress. For that reason a high class kit is not a gasket plus off-the-shelf hardware: the PS-Series set (PS-300 standard, PS-400FS or PS-500HT fire-safe) is matched to the gasket and the flange. Class 1500 and 2500 joints, and API 10K and 15K flanges, normally use the steel-core construction rather than a laminate retainer.
Below Class 900 the Delta construction is usually sufficient and more economical. The step change is the retainer: a laminate carries the seating load up to a point, and above that point the steel core is the dependable choice, which is why the class break sits where it does in the range.
Key features
- ANSI 150–2500 and API 2K–15K coverage in Ranger and Ranger FS
- 316 stainless steel core with duplex, super duplex and Alloy 625 options
- Mechanically retained PTFE spring-energized seal in Ranger
- Serrated PTFE fire-safe construction in Ranger FS (API 6FB Third Edition)
- PS-300, PS-400FS and PS-500HT sleeve and washer sets for the higher classes
- Hardened coated steel backing washers for high bolt loads
- Sizes 1/2"–48", up to 392°F (200°C)
Specifications
| Products | PROTEK RANGER · PROTEK RANGER FS |
|---|---|
| Pressure class | ANSI 900 · 1500 · 2500 and API 6A 10K · 15K |
| Size range | 1/2"–48" |
| Core | 316 SS standard · duplex · super duplex · Alloy 625 (configurator options) |
| Sealing element | PTFE spring-energized (Ranger) · serrated PTFE (Ranger FS) |
| Temperature | Up to 392°F (200°C) |
| Sleeve and washer set | PS-300 standard · PS-400FS · PS-500HT fire-safe |
| Steel washer | Hardened coated steel |
| Retainer options | G10 · G11 |
| Documentation | Certificate of conformance; MTRs on request |
Construction data for the product family. Confirm the specific joint, medium and temperature with Protek Engineering before ordering.
Which Protek products
Typical applications
Wellheads and production trees
High class API flanges on cathodically protected production equipment.
Gas compression and metering
Class 1500 and 2500 joints where bolt load and isolation integrity both matter.
Hydroprocessing and high pressure process
Refinery joints at elevated pressure where a steel core resists the seating load.
Injection and transmission lines
Isolated flange sets on high pressure transmission and injection piping.
Selection & installation notes
Choose the construction first
Class 900 and above is normally Ranger or Ranger FS. Delta covers ANSI 150–900 / API 2K–5K, and Scout stops at ANSI 150–300.
Torque, not guesswork
At these classes the tightening torque decides both seating and retainer stress. Use the torque calculator with the actual gasket, bolting and lubrication, and confirm you are inside both limits before issuing the procedure.
Isolation testing
Verify the break after tightening, and repeat after any flange disturbance. NACE SP0286 practice is the usual reference for buried and submerged joints.
Check the joint with the engineering tools
Frequently asked questions
Which Protek product covers ANSI Class 2500?
+−
Ranger and Ranger FS both cover ANSI 150–2500 and API 2K–15K in sizes 1/2"–48", with Ranger used for general critical service and Ranger FS where a fire-safe gasket is specified.
Are Protek high pressure kits rated for API 15K?
+−
The published range for Ranger and Ranger FS is API 2K–15K. Confirm the specific flange, ring and service with Protek Engineering before ordering.
Why use a steel core instead of a laminate retainer?
+−
A 316 stainless steel core carries the high seating load of a high class joint with less risk of the retainer crushing or relaxing, which is why the steel-core constructions are used above Class 900.
How is the tightening torque set?
+−
From the actual gasket dimensions, bolt size, lubrication and target stress method in the torque calculator, so both the gasket seating stress and the retainer stress limits are satisfied.
Configure the kit for your flange