ASME B16.5 FLANGE DIMENSIONS
& ISOLATION KIT SIZES
Flange geometry and the isolation kit that fits it, in one row. Every size carries the ASME B16.5 weld-neck dimensions — flange OD, thickness, raised face, bolt circle, bolting and hub — together with the Protek Type F and Type E gasket, sleeve, isolating washer, steel washer and calculated stud length for the same joint.
Drawn to scale from ASME B16.5 weld-neck dimensions; illustration only. T and Y exclude the raised face (B16.5-2017 and later); add the RF height for overall length.
- Flange OD (O)
- 10"
- Thickness (T, excl. RF)
- 1.19"
- Raised face Ø (R)
- 6.19"
- Raised face height
- 0.06"
- Bolt circle (BC)
- 7.88"
- Bolting
- 8 × Ø3/4-10 UNC
- Bolt hole Ø
- 0.88"
- Hub Ø at base (X)
- 5.75"
- Length through hub (Y, excl. RF)
- 3.32"
| NPS | OD | T | RF Ø | BC | Bolts | Hole Ø | Type F ID × OD | Sleeve OD × L | Stud L | Open |
|---|---|---|---|---|---|---|---|---|---|---|
| 1/2" | 3.75 | 0.5 | 1.38 | 2.62 | 4 × Ø1/2-13 UNC | 0.63 | 0.632 × 2 | 0.578 × 1.563 | 3.50 | |
| 3/4" | 4.62 | 0.56 | 1.69 | 3.25 | 4 × Ø5/8-11 UNC | 0.75 | 0.834 × 2.5 | 0.703 × 1.688 | 3.75 | |
| 1" | 4.88 | 0.62 | 2 | 3.5 | 4 × Ø5/8-11 UNC | 0.75 | 1.059 × 2.75 | 0.703 × 1.813 | 4.00 | |
| 1-1/4" | 5.25 | 0.69 | 2.5 | 3.88 | 4 × Ø5/8-11 UNC | 0.75 | 1.39 × 3.125 | 0.703 × 2 | 4.00 | |
| 1-1/2" | 6.12 | 0.75 | 2.88 | 4.5 | 4 × Ø3/4-10 UNC | 0.88 | 1.62 × 3.625 | 0.828 × 2.063 | 4.50 | |
| 2" | 6.5 | 0.81 | 3.62 | 5 | 8 × Ø5/8-11 UNC | 0.75 | 2.077 × 4.25 | 0.703 × 2.188 | 4.25 | |
| 2-1/2" | 7.5 | 0.94 | 4.12 | 5.88 | 8 × Ø3/4-10 UNC | 0.88 | 2.479 × 5 | 0.828 × 2.5 | 4.75 | |
| 3" | 8.25 | 1.06 | 5 | 6.62 | 8 × Ø3/4-10 UNC | 0.88 | 3.078 × 5.75 | 0.828 × 2.688 | 5.00 | |
| 3-1/2" | 9 | 1.12 | 5.5 | 7.25 | 8 × Ø3/4-10 UNC | 0.88 | 3.558 × 6.375 | 0.828 × 2.813 | 5.25 | |
| 4" | 10 | 1.19 | 6.19 | 7.88 | 8 × Ø3/4-10 UNC | 0.88 | 4.036 × 7 | 0.828 × 3 | 5.25 | |
| 5" | 11 | 1.31 | 7.31 | 9.25 | 8 × Ø3/4-10 UNC | 0.88 | 5.057 × 8.375 | 0.828 × 3.188 | 5.50 | |
| 6" | 12.5 | 1.38 | 8.5 | 10.62 | 12 × Ø3/4-10 UNC | 0.88 | 6.075 × 9.75 | 0.828 × 3.375 | 5.75 | |
| 8" | 15 | 1.56 | 10.62 | 13 | 12 × Ø7/8-9 UNC | 1 | 7.991 × 12 | 0.953 × 3.688 | 6.25 | |
| 10" | 17.5 | 1.81 | 12.75 | 15.25 | 16 × Ø1-8 UN | 1.12 | 10.03 × 14.125 | 1.078 × 4.188 | 7.00 | |
| 12" | 20.5 | 1.94 | 15 | 17.75 | 16 × Ø1-1/8-8 UN | 1.25 | 12.01 × 16.5 | 1.203 × 4.5 | 7.50 | |
| 14" | 23 | 2.06 | 16.25 | 20.25 | 20 × Ø1-1/8-8 UN | 1.25 | 13.26 × 19 | 1.203 × 4.688 | 7.75 | |
| 16" | 25.5 | 2.19 | 18.5 | 22.5 | 20 × Ø1-1/4-8 UN | 1.38 | 15.26 × 21.125 | 1.328 × 5 | 8.25 | |
| 18" | 28 | 2.31 | 21 | 24.75 | 24 × Ø1-1/4-8 UN | 1.38 | 17.26 × 23.375 | 1.328 × 5.188 | 8.50 | |
| 20" | 30.5 | 2.44 | 23 | 27 | 24 × Ø1-1/4-8 UN | 1.38 | 19.26 × 25.625 | 1.328 × 5.5 | 8.75 | |
| 24" | 36 | 2.69 | 27.25 | 32 | 24 × Ø1-1/2-8 UN | 1.63 | 23.26 × 30.375 | 1.578 × 6 | 9.75 |
Inches. Class 300 · Protek Ranger · RF facing · double washer arrangement.
Build the kit for your flange and download the drawing, or send the service conditions to Protek Engineering for a written recommendation and quote.
Flange dimension questions
Which flange type do these dimensions cover?
+−
Weld-neck flanges to ASME B16.5, which is the standard mating flange for an isolation joint. Flange thickness T is given excluding the raised face, so the face-to-face thickness of a joint is T plus the raised-face height on each side. Slip-on, threaded, lap-joint and blind flanges have different dimensions and are not covered by these numbers.
Why does the thickness differ from a slip-on table?
+−
Weld-neck and slip-on flanges are not the same forging, so ASME B16.5 lists different thicknesses for the same class and size. The configurator, the drawings, the 3D model and every tool on this site use the weld-neck values, and the flange dimensions here are those same values.
Where do the gasket, sleeve and washer sizes come from?
+−
From the Protek standard charts, through the same kit engine that drives the configurator: the Type F outside diameter is the bolt circle minus the bolt hole diameter, the Type E outside diameter is the flange OD, the gasket ID is the Protek pipe bore, and the sleeve and washer sizes are derived from the bolt diameter and hole with the Protek wall and clearance rules.
Why is the sleeve shorter than the full stack?
+−
The sleeve must pass through both bolt holes and stop at the inner face of the steel backing washers, so it cannot run into them. Its length is the shortest of the Protek chart value, the chart rule recomputed on the weld-neck thickness, and the fit limit — rounded down to the nearest 1/16 inch.