Gasket Types

Large Diameter Isolation Gaskets

Up to 120" in the Delta range

Large diameter isolation joints are their own problem. A big flange is harder to keep flat, the bolt circle carries more studs that all have to share the load evenly, and the gasket has to stay seated across a long circumference where a small amount of relaxation in one area opens a leak path. Handling, alignment and the sequence used for tightening matter as much as the gasket itself.

Protek Delta is the product built for this range: 1/2" through 120", ANSI 150–900 and API 2K–5K, with an incline-plane groove geometry and a self-energizing Quad seal that needs lower bolt loads to seat — useful where the available bolt load on a large flange spread over many studs is the limiting factor. Scout covers 1/2"–24" and Ranger and Ranger FS 1/2"–48", so above those sizes Delta is normally the family in the discussion. ASME B16.47 Series A and B flanges, and specialty or non-standard large flanges, are reviewed by Protek Engineering before quotation.

Above 48 inches the practical questions are less about the gasket than about support, alignment and how the joint will be tightened. Send the flange standard, bolt circle and the bolt load the tensioning equipment can deliver, and the joint is worked through before anything is ordered.

Key features

  • Delta range covers 1/2"–120" in ANSI 150–900 / API 2K–5K
  • Self-energizing Quad seal lowers the bolt load needed to seat the gasket
  • G10 or G11 retainer in a single-piece large diameter construction
  • Sleeves and washers sized per bolt circle for the whole joint
  • ASME B16.47 Series A and B and specialty flanges reviewed per project
  • Certificate of conformance as standard, MTRs on request

Specifications

Large Diameter Isolation Gaskets construction and range data
ProductPROTEK DELTA (large diameter)
Size range1/2"–120"
Pressure classANSI 150–900 · API 2K–5K
Flange standardsASME B16.5 · ASME B16.47 Series A and B reviewed per project
RetainerG10 · G11
Sealing elementSelf-energizing Quad seal
Gasket stylesType E (full face) · Type F (raised face)
Sleeve and washer setPS-100 · PS-200 · PS-300
DocumentationCertificate of conformance; MTRs on request
OriginManufactured in the US and internationally

Construction data for the product family. Confirm the specific joint, medium and temperature with Protek Engineering before ordering.

Typical applications

Transmission pipelines

Large diameter isolated flange sets on coated, cathodically protected transmission lines.

Water and wastewater trunk mains

Big diameter plant and distribution flanges requiring an electrical break.

Treatment and process vessels

Vessel and tank nozzles where the flange is large and alignment is difficult.

Power plant circulating water

Large cooling water flanges on protected systems.

Selection & installation notes

Bolt load and relaxation

On a large joint, torque the studs in a cross pattern in more than three passes and re-check after the joint has been in service. Lower-bolt-load geometries help where the flange cannot deliver high stud stress.

Handling and alignment

Support the gasket during fit-up, keep it flat, and never pull the flanges together with the studs. Misalignment on a large joint shows up as a leak at one arc of the circumference.

Non-standard flanges

ASME B16.47 Series A and B and specialty large flanges are reviewed with Protek Engineering against the actual dimensions before quotation.

FAQ

Frequently asked questions

What is the largest isolation gasket Protek supplies?

+

The published Delta range runs from 1/2" to 120". Above that, or for non-standard large flanges, the joint is reviewed by Protek Engineering.

Are ASME B16.47 Series A and B flanges supported?

+

They are reviewed per project against the actual flange dimensions. Send the standard, series, size and class with the service conditions for a quotation.

Why does Delta suit large diameter joints?

+

Its incline-plane geometry with a self-energizing Quad seal needs lower bolt loads to seat, which helps on a large bolt circle where the available stud stress is spread across many bolts.

How should a large isolation joint be tightened?

+

In a cross pattern over several passes, with a re-check after the line is in service. Confirm the target torque in the calculator using the actual gasket and bolt data.

Ready to specify?

Configure the kit for your flange

Build the gasket, sleeve and washer set for your flange and download the drawing and bill of materials, or send the service conditions to Protek Engineering for a written recommendation.