Components

Mineral-Filled Nylon Isolating Sleeves

Tough, abrasion-resistant sleeve option

Mineral-filled nylon is a tough, abrasion-resistant engineering plastic, and Protek offers it as a sleeve option where handling damage or mechanical wear is the concern rather than temperature. A nylon sleeve resists scuffing and impact during fit-up better than a thin film, and it machines cleanly to a wall that clears the bolt hole.

Its limitation is moisture. Nylon absorbs water, and a sleeve that absorbs water changes dimension and loses electrical strength in wet service. For that reason a mineral-filled grade is used rather than an unfilled nylon, and the material is offered as a custom option instead of being a standard PS-Series sleeve: it suits a specific joint where the service is dry enough and the mechanical argument is strong.

Where a standard set is wanted, the choice remains Mylar for economy, G10 for general industrial duty and Nomex for high temperature. Nylon is the answer to a particular question — abrasion on a joint that is assembled and disassembled, or a sleeve that has to shrug off rough handling — and the temperature and medium are checked before it is recommended.

Typical properties

Typical properties of Mineral-filled nylon
StandardMineral-filled PA
Dielectric strength (typical)400–600 V/mil
Temperature220°F
Water absorptionAbsorbs moisture
NotesTough and abrasion resistant, but absorbs moisture — dimensional change and loss of electrical strength in wet service.

Typical values for comparison, not specifications. Actual properties vary by manufacturer, thickness, construction and test method.

Sizing

  • Inside diameter sized from the bolt diameter with running clearance.
  • Wall thickness approximately 0.031" for a nylon sleeve.
  • Outside diameter checked against the flange bolt hole before release.
  • Length follows the distance between the isolating washers, through both flanges and the gasket.

Moisture absorption is the deciding limitation for nylon: confirm the service is dry and the temperature is within its range.

Flange dimensions tool

Where it is used

Custom component sets

Offered as a sleeve option where abrasion resistance or handling toughness is the deciding factor.

View page

PS-Series sets

The standard sets use Mylar, G10 and Nomex sleeves; nylon is quoted as a custom option.

View page

Chemical compatibility

Check the medium against mineral-filled nylon before specifying.

View page

Sizes and how to order

Sizes available

1/2" to 24" ASME B16.5 bolting as a custom option. Larger and specialty sizes on request.

How to order

Nylon sleeves are quoted as a custom component. Send the bolt size, flange class, medium and temperature to Protek Engineering for a recommendation.

Chemical compatibility snapshot

Ratings at ambient temperature from the chemical compatibility matrix, which covers 44 media. A snapshot is shown here — open the tool for the full matrix and the service temperature notes.

Mineral-filled Nylon

Holds up against

Crude oil, sweet · Natural gas, dry · Carbon dioxide, dry · Hydrogen gas · Nitrogen / air

Limited or not recommended

Produced water (H2S/CO2/chlorides) · Steam (to 300°F) (not recommended) · Hydrochloric acid, dilute (<10%) (not recommended) · Hydrochloric acid, concentrated (not recommended) · Sulfuric acid, dilute (<10%) (not recommended)

Full chemical compatibility matrix
FAQ

Frequently asked questions

Why use mineral-filled nylon for a sleeve?

+

It is tough and abrasion resistant, so it resists handling and wear better than a thin film sleeve. The mineral fill reduces the dimensional change that unfilled nylon shows when it absorbs water.

Is nylon a standard PS-Series sleeve?

+

No. The standard sets use Mylar, G10 and Nomex. Mineral-filled nylon is offered as a custom option where the joint calls for it.

What is the temperature limit of a nylon sleeve?

+

Around 220°F (104°C) typical, below G10 and well below Nomex.

What is the main limitation of nylon?

+

Moisture absorption. It changes dimension and loses electrical strength in wet service, so it is chosen only where the service is dry.

Ready to specify?

Configure the kit for your flange

Build the gasket, sleeve and washer set for your flange and download the drawing and bill of materials, or send the service conditions to Protek Engineering for a written recommendation.