Type F Raised Face Isolation Gaskets
Raised-face sealing with full bolt isolation
A Type F isolation gasket is the raised-face pattern. The gasket seals on the raised face, its outside diameter sits inside the bolt circle, and the bolt holes are left open so full-length sleeves can pass through. Because the raised face is a defined, confined seating area, the gasket is compressed over a smaller area than a full-face gasket, which concentrates the bolt load where the seal is and suits higher pressure classes.
Isolation in a Type F joint comes from three parts working together: the gasket breaks the electrical path across the faces, the sleeves break it through every bolt hole, and the isolating washers break it under every nut and bolt head. Protek supplies that stack as a kit, so the gasket, sleeve and washer dimensions are matched to the flange rather than being sourced separately. The pattern is available in Scout for economical ANSI 150–300 service, Delta for general industrial duty to ANSI 900 / API 5K, Ranger for 316 stainless steel core construction to ANSI 2500 / API 15K, and Ranger FS where a fire-safe isolation gasket certified to API 6FB Third Edition is required.
A confined seating area also changes how the joint behaves under load. The same bolt load produces a higher gasket stress on a raised face than across a full face, which is useful up to the point where the retainer reaches its limit — the reason both gasket seating and retainer stress are checked when torque is set rather than copied from a table.
Key features
- Sealing element confined by the raised face, inside the bolt circle
- Full-length insulating sleeves through every bolt hole
- Isolating washers under nuts and bolt heads; steel backing washers supplied
- G10 or G11 retainer in Delta; 316 SS core in Ranger and Ranger FS
- Self-energizing Quad seal geometry in Delta lowers the required bolt load
- Rated from ANSI 150 to ANSI 2500 and API 2K to API 15K across the range
- Sizes 1/2"–120" in Delta and 1/2"–48" in Ranger and Ranger FS
Specifications
| Gasket style | Type F — raised face, gasket OD inside the bolt circle |
|---|---|
| Flange facing | Raised face (RF) |
| Retainer | G10 · G11 · 316 SS core, by product |
| Sealing element | Nitrile · PTFE spring-energized · serrated PTFE (fire safe) |
| Size range | 1/2"–24" Scout · 1/2"–120" Delta · 1/2"–48" Ranger and Ranger FS |
| Pressure class | ANSI 150–300 Scout · 150–900 Delta · 150–2500 Ranger and Ranger FS |
| Temperature | Up to 392°F (200°C) for Ranger and Ranger FS |
| Bolting | Sleeves through the bolt circle with washers both sides |
| Documentation | Certificate of conformance as standard, MTRs on request |
| Origin | Manufactured in the US and internationally |
Construction data for the product family. Confirm the specific joint, medium and temperature with Protek Engineering before ordering.
Which Protek products
Typical applications
Oil and gas gathering
Raised-face joints on carbon steel lines where cathodic protection must stay isolated from station piping.
Refined product and gas service
Moderate to high pressure raised-face flanges in ANSI 300–900 duty.
Chemical processing
Joints where the retainer and sealing element are selected against the medium from the compatibility data.
Power generation
Cooling water, service water and auxiliary raised-face piping requiring an electrical break.
Selection & installation notes
Type F or Type E?
The facing decides the pattern: RF flanges take Type F, FF flanges take Type E. Fitting a full-face gasket to a raised-face joint, or the reverse, leaves the seal outside its designed contact area.
Bolt load
Confined raised-face seating means the available bolt load is concentrated on a small area. Run the joint in the torque calculator to confirm gasket seating and to set a tightening torque that does not over-stress the retainer.
Verification
After tightening in a cross pattern, check continuity between the two flanges and between each stud and each flange. NACE SP0286 describes accepted isolation testing practice for buried and submerged joints.
Check the joint with the engineering tools
Frequently asked questions
What is the difference between a Type F and a Type E gasket?
+−
Type F seals inside the bolt circle on a raised face and leaves the bolt holes open for sleeves; Type E is a full-face gasket whose outside diameter matches the flange and whose bolt holes are covered. Raised-face flanges use Type F.
Can a Type F gasket be used on flat-face flanges?
+−
Type F is designed for raised-face joints. On flat-face flanges there is no raised ring to confine the gasket, so the full-face Type E pattern is used instead.
Do Type F kits include the sleeves and washers?
+−
Yes. A Protek kit supplies the gasket, full-length insulating sleeves, isolating washers and steel backing washers sized to the flange, so every stud is isolated.
Which product should I choose for a high class joint?
+−
Delta covers ANSI 150–900 / API 2K–5K. Above that, Ranger (316 SS core) and Ranger FS (fire-safe, API 6FB Third Edition) cover ANSI 150–2500 / API 2K–15K.
Configure the kit for your flange
Build the gasket, sleeve and washer set for your flange and download the drawing and bill of materials, or send the service conditions to Protek Engineering for a written recommendation.