Flange Isolation Gasket Kits
Gasket, full-length sleeves, isolating washers and steel backing washers
A flange isolation gasket kit is the complete electrical break for one bolted joint. The gasket isolates the two flange faces, full-length insulating sleeves isolate every stud from both flanges, isolating washers isolate each nut and bolt head, and steel backing washers take the bearing load so the insulating washers are not crushed. Used together, these parts make the joint a true dielectric break rather than a gasket with an uninsulated bolt circle.
Isolation joints exist for three reasons. On cathodically protected pipelines the flange must not short the coated, protected steel to a grounded or bare structure, because the current that should be protecting the line would leave through the joint. Where two different metals meet, a gasket and sleeve set removes the electrical path that drives galvanic corrosion at the flange. And on systems exposed to stray current — traction power, nearby rectifiers, impressed-current systems — an isolated flange keeps that current out of the piping or keeps it inside it, depending on the design.
A kit is not the only way to buy an isolation joint. The gasket can be ordered on its own where the sleeves and washers are already held, and individual components can be supplied as spares. A kit is the practical choice for a new joint because the gasket, sleeve and washer dimensions are matched to the flange and to each other: a sleeve that does not clear the bolt hole, or an isolating washer that is too thin for the bolt load, defeats the isolation just as surely as a plain gasket. Protek kits are assembled from the product family that suits the joint — Scout, Delta, Ranger or Ranger FS — with a PS-Series sleeve and washer set matched to the service.
What a kit contains
Isolation gasket
The isolating element between the faces. Type E covers the whole flange face; Type F seals inside the bolt circle on a raised face. Retainer and sealing materials follow the service.
Gasket typesFull-length insulating sleeves
One sleeve through each bolt hole, long enough to pass through both flanges and the gasket so no stud touches flange steel anywhere along its length.
Sleeve materialsIsolating washers
Under every nut and bolt head, sized to spread the bolt load without crushing and to keep the hardware clear of the flange face.
Washer optionsSteel backing washers
Hardened or zinc-plated steel washers between the nut and the isolating washer, so the tightening load is carried by steel rather than by the laminate.
PS-Series setsWhy a flange is isolated
Cathodic protection
A shorted flange drains the protection current from a coated line. Isolation keeps the current on the pipe and the protected potential where it belongs.
Galvanic corrosion
Two dissimilar metals in an electrolyte form a cell. Breaking the electrical path removes the driving circuit, so the less noble flange is no longer consumed.
Stray current
Traction systems, welding sets and impressed-current equipment push current through structures they were never designed to carry. Isolated flanges bound that path.
Kit, gasket only or loose components
All three are available. The difference is who takes responsibility for the hardware dimensions that make the break work.
| Complete kit | Gasket only | Components | |
|---|---|---|---|
| Electrical break across the faces | Yes — isolating gasket | Yes — isolating gasket | Yes, if the right gasket is ordered |
| Electrical break through every stud | Yes — sleeves and washers | No | Yes, if every part is ordered |
| Dimensions matched to the flange | Yes — selected in the configurator | Gasket only | Buyer's responsibility |
| Hardware sizing for the bolt load | Yes — PS-Series set | Not addressed | Buyer's responsibility |
| Typical use | New isolated joints | Replacement of a known part | Spares and repairs |
Type E, Type F and Type D
The flange facing decides the gasket pattern. Type D covers ring-type joint flanges, which are engineered per joint rather than selected from a table.
| Type E | Type F | Type D | |
|---|---|---|---|
| Sealing position | Whole flange face | Raised face, inside the bolt circle | RTJ groove — engineered per joint |
| Flange facing | Flat face (FF) | Raised face (RF) | Ring type joint (RTJ) |
| Gasket outside diameter | Matches the flange OD | Inside the bolt circle | Per configuration |
| Bolt holes | Through the gasket | Open, sleeves only | Open, sleeves only |
| Typical service | Low and moderate pressure plant piping | General to high pressure joints | High pressure RTJ joints |
Product family comparison
Four families cover the range from economical Class 150 plant piping to ANSI 2500 and API 15K critical and fire-safe service.
| Product | Retainer & seal | Sizes | Classes | Temperature | Best for |
|---|---|---|---|---|---|
| PROTEK SCOUT | Phenolic, nitrile sealing | 1/2"–24" | ANSI 150–300 / PN20–50 | Moderate service | Economical isolation, moderate pressures |
| PROTEK DELTA | G10 or G11, Quad seal | 1/2"–120" | ANSI 150–900 / API 2K–5K | General industrial | General industry and large diameters |
| PROTEK RANGER | 316 SS core, PTFE spring-energized seal | 1/2"–48" | ANSI 150–2500 / API 2K–15K | Up to 392°F (200°C) | Critical and extreme service |
| PROTEK RANGER FS | API 6FB Third Edition, serrated PTFE | 1/2"–48" | ANSI 150–2500 / API 2K–15K | Up to 392°F (200°C) | Fire-safe isolation joints |
Installation overview
- 1Check the kit against the flange: gasket pattern (Type E or Type F), bolt circle, bolt size and sleeve length. The flange dimensions tool gives the ASME B16.5 data and the matching Protek sizes.
- 2Clean both flange faces and the bolt holes. Rust, scale or old gasket material under the gasket changes the compression and can bridge the isolation.
- 3Fit the gasket and confirm it is centred, with every bolt hole aligned and the sealing element fully supported.
- 4Insert a full-length sleeve in each hole, then the isolating washer, then the steel backing washer, under both nut and bolt head.
- 5Tighten in a cross pattern in at least three passes to the torque from the calculator, using the lubrication assumed in the calculation.
- 6Verify the electrical break with a continuity test before the line is commissioned, and repeat it after any flange disturbance. NACE SP0286 practice is the usual reference for buried and submerged joints.
Isolation gasket types
Engineering tools for the joint
Every tool is free to use: size the kit, check the bolt load, confirm the materials and work out the stud length before the joint is ordered.
Flange isolation kit questions
What is included in a flange isolation gasket kit?
+−
A gasket, one full-length insulating sleeve per bolt hole, isolating washers for every nut and bolt head, and steel backing washers. The parts are sized to the flange and to each other so the whole joint is isolated.
Can I buy the isolation gasket without the sleeves and washers?
+−
Yes, gaskets and individual components can be supplied separately for replacements and spares. A complete kit is normally used for a new joint, because the gasket, sleeve and washer dimensions have to match.
How do I know whether I need Type E or Type F?
+−
The flange facing decides it. Flat-face flanges use the full-face Type E pattern, raised-face flanges use Type F, and RTJ flanges need an engineered configuration agreed with Protek Engineering.
How is an isolation joint verified after installation?
+−
With an electrical continuity test across the joint — flange to flange, and each stud to each flange — after final tightening. NACE SP0286 practice is the usual reference for buried and submerged joints.
Configure the kit for your flange
Build the gasket, sleeve and washer set for your flange and download the drawing and bill of materials, or send the service conditions to Protek Engineering for a written recommendation.