Isolation Gaskets

Flange Isolation Gasket Kits

Gasket, full-length sleeves, isolating washers and steel backing washers

A flange isolation gasket kit is the complete electrical break for one bolted joint. The gasket isolates the two flange faces, full-length insulating sleeves isolate every stud from both flanges, isolating washers isolate each nut and bolt head, and steel backing washers take the bearing load so the insulating washers are not crushed. Used together, these parts make the joint a true dielectric break rather than a gasket with an uninsulated bolt circle.

Isolation joints exist for three reasons. On cathodically protected pipelines the flange must not short the coated, protected steel to a grounded or bare structure, because the current that should be protecting the line would leave through the joint. Where two different metals meet, a gasket and sleeve set removes the electrical path that drives galvanic corrosion at the flange. And on systems exposed to stray current — traction power, nearby rectifiers, impressed-current systems — an isolated flange keeps that current out of the piping or keeps it inside it, depending on the design.

A kit is not the only way to buy an isolation joint. The gasket can be ordered on its own where the sleeves and washers are already held, and individual components can be supplied as spares. A kit is the practical choice for a new joint because the gasket, sleeve and washer dimensions are matched to the flange and to each other: a sleeve that does not clear the bolt hole, or an isolating washer that is too thin for the bolt load, defeats the isolation just as surely as a plain gasket. Protek kits are assembled from the product family that suits the joint — Scout, Delta, Ranger or Ranger FS — with a PS-Series sleeve and washer set matched to the service.

What a kit contains

Isolation gasket

The isolating element between the faces. Type E covers the whole flange face; Type F seals inside the bolt circle on a raised face. Retainer and sealing materials follow the service.

Gasket types

Full-length insulating sleeves

One sleeve through each bolt hole, long enough to pass through both flanges and the gasket so no stud touches flange steel anywhere along its length.

Sleeve materials

Isolating washers

Under every nut and bolt head, sized to spread the bolt load without crushing and to keep the hardware clear of the flange face.

Washer options

Steel backing washers

Hardened or zinc-plated steel washers between the nut and the isolating washer, so the tightening load is carried by steel rather than by the laminate.

PS-Series sets

Why a flange is isolated

Cathodic protection

A shorted flange drains the protection current from a coated line. Isolation keeps the current on the pipe and the protected potential where it belongs.

Galvanic corrosion

Two dissimilar metals in an electrolyte form a cell. Breaking the electrical path removes the driving circuit, so the less noble flange is no longer consumed.

Stray current

Traction systems, welding sets and impressed-current equipment push current through structures they were never designed to carry. Isolated flanges bound that path.

Kit, gasket only or loose components

All three are available. The difference is who takes responsibility for the hardware dimensions that make the break work.

Isolation kit compared with a gasket-only purchase and loose components
Complete kitGasket onlyComponents
Electrical break across the facesYes — isolating gasketYes — isolating gasketYes, if the right gasket is ordered
Electrical break through every studYes — sleeves and washersNoYes, if every part is ordered
Dimensions matched to the flangeYes — selected in the configuratorGasket onlyBuyer's responsibility
Hardware sizing for the bolt loadYes — PS-Series setNot addressedBuyer's responsibility
Typical useNew isolated jointsReplacement of a known partSpares and repairs

Type E, Type F and Type D

The flange facing decides the gasket pattern. Type D covers ring-type joint flanges, which are engineered per joint rather than selected from a table.

Type E, Type F and Type D isolation gasket comparison
Type EType FType D
Sealing positionWhole flange faceRaised face, inside the bolt circleRTJ groove — engineered per joint
Flange facingFlat face (FF)Raised face (RF)Ring type joint (RTJ)
Gasket outside diameterMatches the flange ODInside the bolt circlePer configuration
Bolt holesThrough the gasketOpen, sleeves onlyOpen, sleeves only
Typical serviceLow and moderate pressure plant pipingGeneral to high pressure jointsHigh pressure RTJ joints

Product family comparison

Four families cover the range from economical Class 150 plant piping to ANSI 2500 and API 15K critical and fire-safe service.

Protek isolation gasket product family comparison
ProductRetainer & sealSizesClassesTemperatureBest for
PROTEK SCOUTPhenolic, nitrile sealing1/2"–24"ANSI 150–300 / PN20–50Moderate serviceEconomical isolation, moderate pressures
PROTEK DELTAG10 or G11, Quad seal1/2"–120"ANSI 150–900 / API 2K–5KGeneral industrialGeneral industry and large diameters
PROTEK RANGER316 SS core, PTFE spring-energized seal1/2"–48"ANSI 150–2500 / API 2K–15KUp to 392°F (200°C)Critical and extreme service
PROTEK RANGER FSAPI 6FB Third Edition, serrated PTFE1/2"–48"ANSI 150–2500 / API 2K–15KUp to 392°F (200°C)Fire-safe isolation joints

Installation overview

  1. 1Check the kit against the flange: gasket pattern (Type E or Type F), bolt circle, bolt size and sleeve length. The flange dimensions tool gives the ASME B16.5 data and the matching Protek sizes.
  2. 2Clean both flange faces and the bolt holes. Rust, scale or old gasket material under the gasket changes the compression and can bridge the isolation.
  3. 3Fit the gasket and confirm it is centred, with every bolt hole aligned and the sealing element fully supported.
  4. 4Insert a full-length sleeve in each hole, then the isolating washer, then the steel backing washer, under both nut and bolt head.
  5. 5Tighten in a cross pattern in at least three passes to the torque from the calculator, using the lubrication assumed in the calculation.
  6. 6Verify the electrical break with a continuity test before the line is commissioned, and repeat it after any flange disturbance. NACE SP0286 practice is the usual reference for buried and submerged joints.

Engineering tools for the joint

Every tool is free to use: size the kit, check the bolt load, confirm the materials and work out the stud length before the joint is ordered.

FAQ

Flange isolation kit questions

What is included in a flange isolation gasket kit?

+

A gasket, one full-length insulating sleeve per bolt hole, isolating washers for every nut and bolt head, and steel backing washers. The parts are sized to the flange and to each other so the whole joint is isolated.

Can I buy the isolation gasket without the sleeves and washers?

+

Yes, gaskets and individual components can be supplied separately for replacements and spares. A complete kit is normally used for a new joint, because the gasket, sleeve and washer dimensions have to match.

How do I know whether I need Type E or Type F?

+

The flange facing decides it. Flat-face flanges use the full-face Type E pattern, raised-face flanges use Type F, and RTJ flanges need an engineered configuration agreed with Protek Engineering.

How is an isolation joint verified after installation?

+

With an electrical continuity test across the joint — flange to flange, and each stud to each flange — after final tightening. NACE SP0286 practice is the usual reference for buried and submerged joints.

Ready to specify?

Configure the kit for your flange