G10 Glass-Epoxy Laminate
The standard dielectric retainer
G10 is a glass fabric reinforced epoxy laminate, made to NEMA LI 1 and MIL-I-24768/2. It is the material Protek uses as the standard dielectric retainer in Delta, as a retainer option in Ranger and Ranger FS, and as the standard sleeve and isolating washer material in the PS-300 and PS-400FS sets — so on a Delta joint the same material often appears in three places.
The reason is the balance of properties. G10 has high dielectric strength in the dry condition, low moisture absorption, and a typical compressive strength of about 65,000 psi, so it carries a real bolt load across a 1/8" section without crushing while holding a wide electrical margin. It is also stable: it does not creep like a thermoplastic and it absorbs very little water compared with paper-based laminates or nylon, so performance does not drift on a joint that lives outdoors or buried.
Its limit is temperature. Typical service is around 284°F (140°C); above that, G11 is used, and for the highest laminate temperature capability G7 glass-silicone. G10 is also strong in compression but should not be asked to take a shock load, which is why the isolating washers it forms are always backed by steel washers that take the nut rotation.
Composition and standards
| Standard | NEMA LI 1 (G10) · MIL-I-24768/2 |
|---|---|
| Construction | Glass fabric reinforcement, epoxy resin |
| Protek use | Delta retainer, Ranger and Ranger FS retainer option, PS-300 and PS-400FS sleeves and isolating washers |
| Product forms | Sheet, machined retainers, sleeves and washers |
| Configurator option | Retainer G10 · sleeve G10 · isolating washer G10 |
Typical properties
| Standard | NEMA G10 / MIL-I-24768/2 |
|---|---|
| Dielectric strength (typical) | 800 V/mil — short-time, Condition A |
| Compressive strength (typical) | 65,000 psi |
| Temperature | 284°F (140°C) |
| Water absorption | ≤0.25% |
| Notes | The standard dielectric retainer: high compressive strength, low moisture pick-up, good electrical strength in the dry condition. |
Typical values for comparison, not specifications. Actual properties vary by manufacturer, thickness, construction and test method.
Electrically insulating, not galvanic
G10 Glass-Epoxy Laminate is non-metallic, so it forms no galvanic couple with the flange, the studs or the pipe. That is its purpose in the assembly: it provides the dielectric break rather than a noble surface. The dielectric values in the table above are the numbers that matter, together with the temperature and moisture limits recorded on this page.
How an isolation joint breaks the coupleWhich Protek products use it
Limits and cautions
- Service temperature around 284°F (140°C) typical — G11 or G7 above that.
- A laminate, not a metal: it carries compression, not a shock or bending load.
- Dielectric strength is a short-time dry-condition value; long-term wet performance depends on the moisture pick-up staying low.
Chemical compatibility snapshot
Ratings at ambient temperature from the chemical compatibility matrix, which covers 44 media. A snapshot is shown here — open the tool for the full matrix and the service temperature notes.
G10
Holds up against
Water, fresh/cooling · Seawater / brine · Produced water (H2S/CO2/chlorides) · Crude oil, sweet · Crude oil, sour (H2S)
Limited or not recommended
Steam (to 300°F) · Hydrochloric acid, concentrated · Sulfuric acid, concentrated (93–98%) (not recommended) · Nitric acid, dilute (<10%) · Nitric acid, concentrated (not recommended)
Frequently asked questions
What is G10 made of?
+−
Glass fabric reinforcement in an epoxy resin, supplied to NEMA LI 1 and MIL-I-24768/2.
What is G10's dielectric strength?
+−
About 800 V/mil short-time in the dry condition, a typical value for comparison rather than a specification.
Where does G10 appear in a Protek kit?
+−
As the Delta retainer, as a retainer option in Ranger and Ranger FS, and as the sleeve and isolating washer material in PS-300 and PS-400FS.
G10 or G11?
+−
G10 below about 284°F (140°C). G11 retains more strength at temperature and is used above that, for example in PS-500HT.
Configure the kit for your flange
Build the gasket, sleeve and washer set for your flange and download the drawing and bill of materials, or send the service conditions to Protek Engineering for a written recommendation.