Steel Core Isolation Gaskets
316 SS, duplex, super duplex and Alloy 625 cores
A steel core isolation gasket uses a metal plate as the structural element of the gasket instead of a laminate. The core carries the bolt load and keeps the gasket geometry stable under compression, while the sealing element — in Ranger, a mechanically retained PTFE spring-energized seal — does the sealing. On a high class joint that separation matters: a laminate retainer can relax, creep or crack when the seating load is concentrated on a small raised-face area, whereas a metal core holds its shape and keeps the seal under load.
Protek's steel core family is Ranger and Ranger FS. The core is 316 stainless steel as standard, with duplex, super duplex and Alloy 625 available as options in the kit configurator for services where the standard grade is not the right answer — chloride-bearing or sour production, for example. Ranger covers 1/2" to 48", ANSI 150–2500 and API 2K–15K up to 392°F (200°C); Ranger FS adds fire-safe performance certified to API 6FB Third Edition. Electrical isolation still comes from the full assembly: the sealing elements, the sleeves through every bolt hole and the isolating washers under every nut and head.
Because the seal is mechanically retained rather than bonded, it stays in place during handling and fit-up. On a large or awkward joint, where a loose sealing element is difficult to seat and easy to dislodge, that is a practical advantage as much as a technical one.
Key features
- 316 stainless steel core as standard for dimensional stability under high bolt load
- Duplex, super duplex and Alloy 625 core options in the configurator
- Mechanically retained PTFE spring-energized sealing element
- Serrated PTFE fire-safe variant in Ranger FS (API 6FB Third Edition)
- Sizes 1/2"–48", ANSI 150–2500 / API 2K–15K, up to 392°F (200°C)
- G10 or G11 retainer options and PS-Series sleeve and washer sets
- Certificate of conformance as standard, MTRs on request
Specifications
| Products | PROTEK RANGER · PROTEK RANGER FS |
|---|---|
| Core material | 316 SS standard · duplex · super duplex · Alloy 625 options |
| Sealing element | PTFE spring-energized, mechanically retained (Ranger) |
| Fire-safe variant | Serrated PTFE, certified to API 6FB Third Edition (Ranger FS) |
| Size range | 1/2"–48" |
| Pressure class | ANSI 150–2500 · API 2K–15K |
| Temperature | Up to 392°F (200°C) |
| Retainer options | G10 · G11 |
| Sleeve and washer set | PS-300 · PS-400FS · PS-500HT |
| Documentation | Certificate of conformance; MTRs on request |
Construction data for the product family. Confirm the specific joint, medium and temperature with Protek Engineering before ordering.
Which Protek products
Typical applications
Sour and chloride-bearing service
Produced water, seawater and chloride-bearing streams where the core grade is selected against the medium.
High class flanges
Class 1500 and 2500 joints where the core resists the concentrated seating load.
Offshore and marine
Cathodically protected systems where atmospheric chlorides are part of the design case.
Large and non-standard flanges
Dimensional stability on sizes where a laminate retainer is less predictable under load.
Selection & installation notes
Core grade selection
316 SS is the standard core. Duplex, super duplex and Alloy 625 are chosen where the service calls for them; the galvanic and chemical tools help narrow the choice, but the final grade is an engineering decision.
Isolation is still the assembly
The core is inside the gasket. The electrical break through the bolting is provided by sleeves and washers, so they are specified with the gasket and verified after installation.
Bolting
High class steel core joints are torque sensitive: confirm both gasket seating and retainer stress in the torque calculator before issuing a bolting procedure.
Check the joint with the engineering tools
Frequently asked questions
What is a steel core isolation gasket?
+−
It is an isolation gasket whose structural element is a metal plate, normally 316 stainless steel, with a separate sealing element. The core carries the bolt load and keeps the gasket geometry stable under compression.
Which core material should I choose?
+−
316 SS is standard. Duplex, super duplex and Alloy 625 are available as options where chloride-bearing or more aggressive service makes them the better choice, confirmed by Protek Engineering.
Does a metal core short out the electrical isolation?
+−
The core is a sealed element inside the gasket and does not connect the two flanges. The break through the bolting is made by the sleeves and isolating washers, and it should be verified after assembly.
What is the difference between Ranger and Ranger FS?
+−
Both use a steel core. Ranger uses a mechanically retained PTFE spring-energized seal; Ranger FS uses serrated PTFE sealing and is certified fire-safe to API 6FB Third Edition.
Configure the kit for your flange
Build the gasket, sleeve and washer set for your flange and download the drawing and bill of materials, or send the service conditions to Protek Engineering for a written recommendation.