Flange Isolation Sleeves
One sleeve per bolt hole — the break through the bolting
A full-length insulating sleeve is the part that keeps each stud clear of flange steel. There is one sleeve per bolt hole, long enough to pass right through both flanges and the gasket, so the stud never touches the bore of a bolt hole. Without a sleeve the gasket and the washers isolate the faces but the bolting still short-circuits the joint, which is why a sleeve is part of the kit rather than an accessory.
Protek supplies sleeves in four materials. Mylar polyester film is the economical choice for moderate-temperature work, G10 glass-epoxy is the standard industrial sleeve, mineral-filled nylon is a tough option where abrasion resistance matters, and Nomex aramid paper is the high-temperature sleeve in the PS-500HT fire-safe set. Each is matched to an isolating washer and a steel backing washer for the same duty, so the whole stack carries one temperature and one electrical rating instead of three.
Sleeve sizing is a clearance problem with very little room in it: the sleeve has to pass over the stud and inside the flange bolt hole at the same time. Protek sizes the sleeve inside diameter from the bolt diameter, sets the wall from the sleeve material, and checks the outside diameter against the ASME B16.5 bolt hole for the class before a kit is released, so a sleeve that is right for one flange class is not assumed right for another.
Sleeve materials compared
| Sleeve material | Dielectric strength (typical) | Temperature | Typical use | PS-Series |
|---|---|---|---|---|
| Mylar (PET film) | 7,000 V/mil thin film | 300°F (150°C) | Economical isolation at moderate temperature | PS-100, PS-200 |
| G10 glass-epoxy | 800 V/mil short-time | 284°F (140°C) | Standard industrial isolation | PS-300, PS-400FS |
| Nomex (aramid paper) | 400–900 V/mil by wall | 428°F (220°C) | High-temperature fire-safe service | PS-500HT |
| Mineral-filled nylon | 400–600 V/mil | 220°F (104°C) | Tough, abrasion-resistant option | Custom sets |
How a sleeve is sized
- Inside diameter: bolt diameter plus a running clearance, so the sleeve slides onto the stud without being stretched.
- Wall thickness: set by the material — a thin film sleeve needs a thinner wall than a glass-epoxy or aramid sleeve for the same dielectric duty.
- Outside diameter: must clear the flange bolt hole. Protek works to a small margin under the hole diameter rather than a nominal fit.
- Length: the full distance between the inner faces of the isolating washers — through both flanges and the gasket — without reaching the steel backing washers, so the sleeve never takes bolt load.
Check the actual hole diameter for the flange size and class in the flange dimensions tool before ordering components on their own.
Flange dimensions toolMaterials in this family
Where it is used
PROTEK SCOUT
Supplied with PS-100 economy or PS-200 enhanced Mylar sleeves for ANSI 150–300 work.
View pageSizes and how to order
Sizes available
1/2" to 24" ASME B16.5 bolting as standard. Larger and specialty bolt sizes are quoted on request.
How to order
Sleeves are ordered as individual components, as a PS-Series sleeve and washer set, or inside a complete isolation kit. The configurator switches to individual components so the sleeve count follows the bolt quantity on the flange.
Chemical compatibility snapshot
Ratings at ambient temperature from the chemical compatibility matrix, which covers 44 media. A snapshot is shown here — open the tool for the full matrix and the service temperature notes.
Mylar (PET)
Holds up against
Water, fresh/cooling · Seawater / brine · Produced water (H2S/CO2/chlorides) · Crude oil, sweet · Crude oil, sour (H2S)
Limited or not recommended
Steam (to 300°F) (not recommended) · Chlorinated solvents · Amines (MEA/DEA/MDEA) (not recommended) · Ammonia, anhydrous · Hydrochloric acid, concentrated
G10
Holds up against
Water, fresh/cooling · Seawater / brine · Produced water (H2S/CO2/chlorides) · Crude oil, sweet · Crude oil, sour (H2S)
Limited or not recommended
Steam (to 300°F) · Hydrochloric acid, concentrated · Sulfuric acid, concentrated (93–98%) (not recommended) · Nitric acid, dilute (<10%) · Nitric acid, concentrated (not recommended)
Nomex
Holds up against
Water, fresh/cooling · Crude oil, sweet · Crude oil, sour (H2S) · Natural gas, dry · Natural gas, wet/sour
Limited or not recommended
Steam (to 300°F) · Hydrochloric acid, dilute (<10%) · Hydrochloric acid, concentrated (not recommended) · Sulfuric acid, dilute (<10%) · Sulfuric acid, concentrated (93–98%) (not recommended)
Mineral-filled Nylon
Holds up against
Crude oil, sweet · Natural gas, dry · Carbon dioxide, dry · Hydrogen gas · Nitrogen / air
Limited or not recommended
Produced water (H2S/CO2/chlorides) · Steam (to 300°F) (not recommended) · Hydrochloric acid, dilute (<10%) (not recommended) · Hydrochloric acid, concentrated (not recommended) · Sulfuric acid, dilute (<10%) (not recommended)
Frequently asked questions
What does a flange isolation sleeve do?
+−
It lines the bolt hole so the stud cannot touch flange steel. Together with the gasket and the isolating washers it completes the electrical break through the joint.
How long should an isolating sleeve be?
+−
Long enough to span the full distance between the inner faces of the two isolating washers — through both flanges and the gasket — and short enough not to reach the steel backing washers, so it never carries bolt load.
Which sleeve material should I choose?
+−
Mylar for economical moderate-temperature work, G10 for standard industrial service, mineral-filled nylon where abrasion resistance matters, and Nomex where the joint has to stay fire-safe above 284°F.
Can I buy isolating sleeves on their own?
+−
Yes. Sleeves are available as individual components, as PS-Series sets, or inside a full isolation kit, and they are sized to the bolt diameter and the flange bolt hole.
Configure the kit for your flange
Build the gasket, sleeve and washer set for your flange and download the drawing and bill of materials, or send the service conditions to Protek Engineering for a written recommendation.