G11 Glass-Epoxy Laminate
Higher-temperature retainer laminate
G11 is the higher-temperature grade of glass-epoxy laminate, to NEMA G11. It uses the same glass reinforcement as G10 with a different resin and cure, and the practical result is that it retains more of its mechanical strength at elevated temperature — at the cost of slightly lower dielectric strength in the dry condition.
Protek uses G11 where temperature is the deciding factor: as a retainer option in Delta, Ranger and Ranger FS, and as the isolating washer in the PS-500HT high-temperature fire-safe set, which runs to the 392°F (200°C) limit of the Ranger FS range. In those joints G11 keeps the isolating elements dimensionally stable when a G10 part would be softening.
Choosing between G10 and G11 is not a quality decision — it is a temperature decision, and the two grades are interchangeable in form and fit. The retainer or washer is specified together with the sleeve and the steel backing washer so the entire stack has one working limit, and above the laminate range entirely the specification moves to G7 glass-silicone or to a steel-core construction.
Composition and standards
| Standard | NEMA G11 |
|---|---|
| Construction | Glass fabric reinforcement, higher-temperature epoxy resin system |
| Protek use | Delta, Ranger and Ranger FS retainer option; PS-500HT isolating washers |
| Product forms | Sheet, machined retainers and washers |
| Configurator option | Retainer G11 · isolating washer G11 |
Typical properties
| Standard | NEMA G11 |
|---|---|
| Dielectric strength (typical) | 400–600 V/mil |
| Compressive strength (typical) | 60,000 psi |
| Temperature | 285–300°F (140–150°C) |
| Water absorption | ≤0.25% |
| Notes | Better strength retention at temperature than G10, with a slightly lower dielectric strength. |
Typical values for comparison, not specifications. Actual properties vary by manufacturer, thickness, construction and test method.
Electrically insulating, not galvanic
G11 Glass-Epoxy Laminate is non-metallic, so it forms no galvanic couple with the flange, the studs or the pipe. That is its purpose in the assembly: it provides the dielectric break rather than a noble surface. The dielectric values in the table above are the numbers that matter, together with the temperature and moisture limits recorded on this page.
How an isolation joint breaks the coupleWhich Protek products use it
Limits and cautions
- Lower dry dielectric strength than G10 — the trade for strength retention at temperature.
- Still a laminate: above its range, G7 or a steel core construction is used.
- Ordered by temperature, not by preference; confirm the design temperature before selecting it.
Chemical compatibility snapshot
Ratings at ambient temperature from the chemical compatibility matrix, which covers 44 media. A snapshot is shown here — open the tool for the full matrix and the service temperature notes.
G11
Holds up against
Water, fresh/cooling · Seawater / brine · Produced water (H2S/CO2/chlorides) · Crude oil, sweet · Crude oil, sour (H2S)
Limited or not recommended
Steam (to 300°F) · Hydrochloric acid, concentrated · Sulfuric acid, concentrated (93–98%) (not recommended) · Nitric acid, dilute (<10%) · Nitric acid, concentrated (not recommended)
Frequently asked questions
What is the difference between G10 and G11?
+−
G11 keeps more of its mechanical strength at temperature, with slightly lower dry dielectric strength. It is chosen when the service temperature is the deciding factor.
What temperature is G11 used to?
+−
It appears in the PS-500HT set, which is used above about 284°F up to the 392°F (200°C) limit of the Ranger FS range.
Are G10 and G11 interchangeable in fit?
+−
Yes — they are the same family in the same forms, so the part number changes with the grade rather than the geometry.
When is G11 not enough?
+−
Above the laminate range entirely: G7 glass-silicone has the highest temperature capability of the laminates, and a steel-core construction takes over where the joint needs a metal plate.
Configure the kit for your flange
Build the gasket, sleeve and washer set for your flange and download the drawing and bill of materials, or send the service conditions to Protek Engineering for a written recommendation.