Potentials in volts against a saturated calomel electrode, most active at the top. Two alloys far apart on this list form a strong couple; two in the same band are effectively safe together.
Galvanic series — flowing seawater, V vs SCEActive ← → Noble
−1.60−1.20−0.80−0.40+0.00+0.40
Zinc / galvanized steel
−1.03…−0.98
Aluminum alloys
−0.90…−0.70
Carbon & low-alloy steel
−0.70…−0.60
300-series stainless (active — crevices / stagnant)
−0.54…−0.43
Aluminum bronze
−0.40…−0.30
Admiralty brass
−0.34…−0.25
Silicon bronze
−0.27…−0.24
400-series stainless (passive)
−0.35…−0.20
90-10 copper-nickel
−0.28…−0.21
70-30 copper-nickel
−0.22…−0.13
17-4 PH stainless
−0.20…−0.10
316 SS (passive)
−0.15…+0.00
Hastelloy C-276
−0.04…+0.10
Rotate your device or widen the window for labels.
| Material | Active end (V) | Noble end (V) | Midpoint (V) |
|---|
| Magnesium | -1.63 | -1.60 | -1.61 |
| Zinc / galvanized steel | -1.03 | -0.98 | -1.00 |
| Aluminum alloys | -0.90 | -0.70 | -0.80 |
| Cadmium | -0.76 | -0.70 | -0.73 |
| Cast iron | -0.72 | -0.60 | -0.66 |
| Carbon & low-alloy steel | -0.70 | -0.60 | -0.65 |
| 300-series stainless (active — crevices / stagnant) | -0.54 | -0.43 | -0.48 |
| Aluminum bronze | -0.40 | -0.30 | -0.35 |
| Brasses | -0.40 | -0.30 | -0.35 |
| Copper | -0.36 | -0.28 | -0.32 |
| Admiralty brass | -0.34 | -0.25 | -0.30 |
| Silicon bronze | -0.27 | -0.24 | -0.26 |
| 400-series stainless (passive) | -0.35 | -0.20 | -0.28 |
| 90-10 copper-nickel | -0.28 | -0.21 | -0.24 |
| Lead | -0.25 | -0.19 | -0.22 |
| 70-30 copper-nickel | -0.22 | -0.13 | -0.17 |
| 17-4 PH stainless | -0.20 | -0.10 | -0.15 |
| Silver | -0.14 | -0.09 | -0.12 |
| Monel 400 | -0.14 | -0.04 | -0.09 |
| Duplex 2205 | -0.07 | -0.07 | -0.07 |
| 316 SS (passive) | -0.15 | 0.00 | -0.07 |
| Super duplex 2507 | -0.01 | -0.01 | -0.01 |
| Titanium | -0.05 | 0.06 | 0.00 |
| Alloy 625 | -0.04 | 0.10 | 0.03 |
| Hastelloy C-276 | -0.04 | 0.10 | 0.03 |
| Platinum | 0.18 | 0.25 | 0.21 |
| Graphite | 0.20 | 0.30 | 0.25 |
300-series stainless steels in low-velocity or poorly aerated water, or inside crevices, may become active and show potentials near −0.5 V.
Passive alloys covered by marine biofilms may shift to +0.3 to +0.4 V.
Flowing seawater at ambient temperature — S.C. Dexter, University of Delaware Sea Grant; ASTM G82; Titanium Information Group (duplex values).
Where the joint is not immersed — atmospheric, buried or dry indoor service — the checker ranks the couple on the anodic index instead of the seawater series. It is a relative table, so only the difference matters.
Anodic Index (MIL-F-14072 Table VI–derived design rule)
| Metal | Volts |
|---|
| Gold | 0.00 |
| Rhodium | 0.05 |
| Silver / Monel / high nickel-copper | 0.15 |
| Nickel, titanium | 0.30 |
| Copper, low brass/bronze, nickel-chromium alloys | 0.35 |
| Brass & bronze | 0.40 |
| High brass & bronze | 0.45 |
| 18% Cr stainless (300-series) | 0.50 |
| Chromium plate, tin plate, 12% Cr stainless | 0.60 |
| Tin-lead solder | 0.65 |
| Lead | 0.70 |
| 2000-series aluminum | 0.75 |
| Carbon & low-alloy steel, cast iron | 0.85 |
| Other wrought / cast aluminum | 0.90 |
| Cast aluminum (non-silicon), cadmium | 0.95 |
| Hot-dip galvanized | 1.20 |
| Zinc / zinc plate | 1.25 |
| Magnesium | 1.75 |
Rule of thumb — max difference
Harsh / marine / outdoor0.15 V
Normal indoor0.25 V
Controlled atmosphere0.50 V
Rule of thumb only — it is not part of MIL-STD-889. Use the potential difference for the specific environment.
Every alloy sits at a natural potential in an electrolyte. Join two of them electrically and the one with the more negative potential becomes the anode: it gives up metal ions, and the cathodic reaction — oxygen reduction in neutral water, hydrogen evolution in acids — runs on the more noble surface. The metals do not have to touch the fluid in the same way; the circuit only needs a continuous metal path and a continuous electrolyte path. In a bolted flange, the studs are the metal path.
A cathodically protected pipeline sitting at a few hundred millivolts below its free potential will try to protect everything it is connected to. If an unprotected flange, a wellhead or a small-diameter branch is bonded through its bolting, the CP system feeds it as well: current drains away, the protected line is under-protected, and the stray current accelerates attack on the neighbouring structure. Isolation stops the drain and keeps each system on its own potential.
An isolating gasket alone isolates nothing: the studs pass straight through the bolt holes and short the two flange faces together. Full-length insulating sleeves line the bolt holes through the full flange thickness, and isolating washers under both nuts and both flange faces keep the nut from contacting the flange. A conventional steel washer on one side defeats the whole kit.
Painting the anode is the intuitive move and usually the wrong one. A coating has holidays — pinholes and scratches — and if only the anode is coated, all of the galvanic current concentrates on that small bare area, so pitting gets worse. Coat the cathode to reduce the cathodic reaction, leave the anode bare or coat both, and never treat a coating as electrical isolation.
A small anode facing a large cathode is the dangerous geometry: all the cathodic current is discharged into a small area of metal, so penetration rate climbs. A stainless flange against a carbon steel spool is worse than the potentials alone suggest, while a large carbon steel flange against a small stainless fitting is comparatively benign. The checker raises the risk one level whenever the cathode is much larger than the anode.
NACE SP0286 covers the electrical isolation of cathodically protected piping. Measure across the joint with a calibrated isolation tester or megohmmeter once the flange is fully torqued, and record the reading on the joint record. If the resistance is effectively zero, a sleeve is short, a washer is trapped, or a metallic component has been substituted — all of which happen in the field more often than the potential difference does.