Engineering Tools

ISOLATION GASKET
BOLT TORQUE TABLES

An isolation gasket only seals when the bolt load is controlled. Too little clamp force leaves the gasket short of seating stress and the joint weeps at start-up; too much crushes the laminate, embeds the isolating washers and can yield the studs. These tables give minimum, recommended and maximum torque for every ASME B16.5 size Protek supports, adjusted for stud material and the nut factor of the lubricant you actually use.

K = 0.16
Protek Ranger FS · Type F — raised face ring · ASTM A193 B7 · K 0.16Need a single joint? Open the torque calculator
Class 15020 sizes · NPS 1/2″–24″
NPSBoltsMinRecommendedMax
1/2″4 × Ø1/2-13 UNC284755
3/4″4 × Ø1/2-13 UNC284755
1″4 × Ø1/2-13 UNC284755
1-1/4″4 × Ø1/2-13 UNC284755
1-1/2″4 × Ø1/2-13 UNC284755
2″4 × Ø5/8-11 UNC5595115
2-1/2″4 × Ø5/8-11 UNC5595115
3″4 × Ø5/8-11 UNC5595115
3-1/2″8 × Ø5/8-11 UNC5595115
4″8 × Ø5/8-11 UNC5595115
5″8 × Ø3/4-10 UNC100165200
6″8 × Ø3/4-10 UNC100165200
8″8 × Ø3/4-10 UNC100165200
10″12 × Ø7/8-9 UNC160270325
12″12 × Ø7/8-9 UNC160270325
14″12 × Ø1-8 UN240405485
16″16 × Ø1-8 UN240405485
18″16 × Ø1-1/8-8 UN355595710
20″20 × Ø1-1/8-8 UN355595710
24″20 × Ø1-1/4-8 UN5008351000

Torque in ft-lb. Select a row for load per bolt and stresses.

Class 30020 sizes · NPS 1/2″–24″
NPSBoltsMinRecommendedMax
1/2″4 × Ø1/2-13 UNC284755
3/4″4 × Ø5/8-11 UNC5595115
1″4 × Ø5/8-11 UNC5595115
1-1/4″4 × Ø5/8-11 UNC5595115
1-1/2″4 × Ø3/4-10 UNC100165200
2″8 × Ø5/8-11 UNC5595115
2-1/2″8 × Ø3/4-10 UNC100165200
3″8 × Ø3/4-10 UNC100165200
3-1/2″8 × Ø3/4-10 UNC100165200
4″8 × Ø3/4-10 UNC100165200
5″8 × Ø3/4-10 UNC100165200
6″12 × Ø3/4-10 UNC100165200
8″12 × Ø7/8-9 UNC160270325
10″16 × Ø1-8 UN240405485
12″16 × Ø1-1/8-8 UN355595710
14″20 × Ø1-1/8-8 UN355595710
16″20 × Ø1-1/4-8 UN5008351000
18″24 × Ø1-1/4-8 UN5008351000
20″24 × Ø1-1/4-8 UN5008351000
24″24 × Ø1-1/2-8 UN89514901790

Torque in ft-lb. Select a row for load per bolt and stresses.

Class 40020 sizes · NPS 1/2″–24″
NPSBoltsMinRecommendedMax
1/2″4 × Ø1/2-13 UNC284755
3/4″4 × Ø5/8-11 UNC5595115
1″4 × Ø5/8-11 UNC5595115
1-1/4″4 × Ø5/8-11 UNC5595115
1-1/2″4 × Ø3/4-10 UNC100165200
2″8 × Ø5/8-11 UNC5595115
2-1/2″8 × Ø3/4-10 UNC100165200
3″8 × Ø3/4-10 UNC100165200
3-1/2″8 × Ø7/8-9 UNC160270325
4″8 × Ø7/8-9 UNC160270325
5″8 × Ø7/8-9 UNC160270325
6″12 × Ø7/8-9 UNC160270325
8″12 × Ø1-8 UN240405485
10″16 × Ø1-1/8-8 UN355595710
12″16 × Ø1-1/4-8 UN5008351000
14″20 × Ø1-1/4-8 UN5008351000
16″20 × Ø1-3/8-8 UN68011301355
18″24 × Ø1-3/8-8 UN68011301355
20″24 × Ø1-1/2-8 UN89514901790
24″24 × Ø1-3/4-8 UN146024302915

Torque in ft-lb. Select a row for load per bolt and stresses.

Class 60020 sizes · NPS 1/2″–24″
NPSBoltsMinRecommendedMax
1/2″4 × Ø1/2-13 UNC284755
3/4″4 × Ø5/8-11 UNC5595115
1″4 × Ø5/8-11 UNC5595115
1-1/4″4 × Ø5/8-11 UNC5595115
1-1/2″4 × Ø3/4-10 UNC100165200
2″8 × Ø5/8-11 UNC5595115
2-1/2″8 × Ø3/4-10 UNC100165200
3″8 × Ø3/4-10 UNC100165200
3-1/2″8 × Ø7/8-9 UNC160270325
4″8 × Ø7/8-9 UNC160270325
5″8 × Ø1-8 UN240405485
6″12 × Ø1-8 UN240405485
8″12 × Ø1-1/8-8 UN355595710
10″16 × Ø1-1/4-8 UN5008351000
12″20 × Ø1-1/4-8 UN5008351000
14″20 × Ø1-3/8-8 UN68011301355
16″20 × Ø1-1/2-8 UN89514901790
18″20 × Ø1-5/8-8 UN115519252305
20″24 × Ø1-5/8-8 UN115519252305
24″24 × Ø1-7/8-8 UN181030203620

Torque in ft-lb. Select a row for load per bolt and stresses.

Class 90019 sizes · NPS 1/2″–24″
NPSBoltsMinRecommendedMax
1/2″4 × Ø3/4-10 UNC100165200
3/4″4 × Ø3/4-10 UNC100165200
1″4 × Ø7/8-9 UNC160270325
1-1/4″4 × Ø7/8-9 UNC160270325
1-1/2″4 × Ø1-8 UN240405485
2″8 × Ø7/8-9 UNC160270325
2-1/2″8 × Ø1-8 UN240405485
3″8 × Ø7/8-9 UNC160270325
4″8 × Ø1-1/8-8 UN355595710
5″8 × Ø1-1/4-8 UN5008351000
6″12 × Ø1-1/8-8 UN355595710
8″12 × Ø1-3/8-8 UN68011301355
10″16 × Ø1-3/8-8 UN68011301355
12″20 × Ø1-3/8-8 UN68011301355
14″20 × Ø1-1/2-8 UN89514901790
16″20 × Ø1-5/8-8 UN115519252305
18″20 × Ø1-7/8-8 UN181030203620
20″20 × Ø2-8 UN221536954435
24″20 × Ø2-1/2-8 UN444074058885

Torque in ft-lb. Select a row for load per bolt and stresses.

Class 150019 sizes · NPS 1/2″–24″
NPSBoltsMinRecommendedMax
1/2″4 × Ø3/4-10 UNC100165200
3/4″4 × Ø3/4-10 UNC100165200
1″4 × Ø7/8-9 UNC160270325
1-1/4″4 × Ø7/8-9 UNC160270325
1-1/2″4 × Ø1-8 UN240405485
2″8 × Ø7/8-9 UNC160270325
2-1/2″8 × Ø1-8 UN240405485
3″8 × Ø1-1/8-8 UN355595710
4″8 × Ø1-1/4-8 UN5008351000
5″8 × Ø1-1/2-8 UN89514901790
6″12 × Ø1-3/8-8 UN68011301355
8″12 × Ø1-5/8-8 UN115519252305
10″12 × Ø1-7/8-8 UN181030203620
12″16 × Ø2-8 UN221536954435
14″16 × Ø2-1/4-8 UN320053356405
16″16 × Ø2-1/2-8 UN444074058885
18″16 × Ø2-3/4-8 UN5970994511340
20″16 × Ø3-8 UN78101301514835
24″16 × Ø3-1/2-8 UN125502091523840

Torque in ft-lb. Select a row for load per bolt and stresses.

Class 250014 sizes · NPS 1/2″–12″
NPSBoltsMinRecommendedMax
1/2″4 × Ø3/4-10 UNC100165200
3/4″4 × Ø3/4-10 UNC100165200
1″4 × Ø7/8-9 UNC160270325
1-1/4″4 × Ø1-8 UN240405485
1-1/2″4 × Ø1-1/8-8 UN355595710
2″8 × Ø1-8 UN240405485
2-1/2″8 × Ø1-1/8-8 UN355595710
3″8 × Ø1-1/4-8 UN5008351000
4″8 × Ø1-1/2-8 UN89514901790
5″8 × Ø1-3/4-8 UN146024302915
6″8 × Ø2-8 UN221536954435
8″12 × Ø2-8 UN221536954435
10″12 × Ø2-1/2-8 UN444074058885
12″12 × Ø2-3/4-8 UN5970994511340

Torque in ft-lb. Select a row for load per bolt and stresses.

Notes & basis
  • Basis: new ASTM A193 B7 studs with ASTM A194 2H heavy hex nuts, hardened steel washers over isolating washers, weld-neck flanges per ASME B16.5, nut factor K = 0.16 (Copper-graphite anti-seize).
  • Dry studs: torque values increase roughly 15–25% — select “Dry / unlubricated” to recalculate.
  • Tighten per ASME PCC-1 using a cross pattern, bringing the joint up in passes and re-checking after the joint reaches operating temperature.
  • Values are calculated guidance only and do not replace joint-specific engineering.
  • Contact Protek for specialty flanges, blinds, slip-ons, lap joints, or non-standard bolting.
Specialty flange?

These tables cover ASME B16.5 weld-neck flanges only. For blinds, slip-ons, lap joints, non-standard or high-temperature joints, Protek will run the joint calculation for your specific bolting.

Contact engineering
FAQ

Isolation gasket bolting questions

How is the torque calculated?

+

Torque follows the short-form equation T = K × F × D, where K is the nut factor, F the clamp load per bolt and D the nominal stud diameter. The clamp load comes from bolt stress: the minimum is S_min × As, the recommended is S_rec × As capped at the joint maximum, and the maximum is the lower of S_max × As and 60% of the stud yield strength × As. Gasket seating stress Y is reported as a check on the average retainer-face stress, not used to set the load.

Why do lubricated studs need less torque?

+

The nut factor K is the share of the applied torque that actually becomes clamp load. A dry thread wastes more torque on friction (K ≈ 0.20), while a fluoropolymer or moly coating lets the same clamp load be reached with roughly 15–25% less torque. Always match the torque table to the lubrication actually used on the joint.

Can I reuse studs and nuts?

+

Protek recommends new bolting for every isolation joint. Reused studs bring unknown nut factor, damaged or galled threads and prior yield, so the torque-to-load relationship is no longer reliable. If reuse is unavoidable, inspect and gauge the threads, replace any nut that has been torqued more than a few times, and use the same lubricant as the original assembly.

What tightening pattern should I use?

+

Follow ASME PCC-1: bring the joint up in passes — about 25%, then 60%, then 100% of the target torque in a star/cross pattern, a further 100% circular pass clockwise until no further nut rotation occurs, and a check pass after roughly four hours. Each row of the calculator carries its own numbered bolt sequence.