Engineering Tools

ISOLATION GASKET
TORQUE CALCULATOR

One joint, fully calculated: minimum, recommended and maximum bolt stress, the stud load each produces, the nut factor of your lubricant, and the retainer and bolt limits reported as checks.

1

Product & gasket style

Protek system and the gasket type in the joint.

S min 20,000 · S rec 30,000 · S max 35,000 psi · Y 2,500 and retainer max 15,000 psi (checks)
2

Flange

ASME B16.5 sizes use the published bolt and gasket geometry.

8 × Ø3/4-10 UNC · Ag 14.19 in²

3

Bolting & lubrication

Stud grade sets yield; lubricant sets the nut factor.

4

Target method

What the calculated torque should achieve.

Recommended torque
100ft-lb
8 bolts · Ø3/4-10 UNC · K 0.16 · 105 ksi bolt yield
Min 65Max 115
Selected value 100 ft-lb of a 65–115 ft-lb range
Bolt stress (% of yield)30,000 psi · 29%
Retainer-face stress (rec.)5,657 psi of 15,000 max
S_min = 20,000 psiS_rec = 30,000 psiS_max = 35,000 psi0.60 × yield = 63,000 psi
Load / bolt
10,034 lbf
44.6 kN
Total clamp load
80,271 lbf
357.0 kN
Tensile stress area
0.334 in²
Ø3/4-10 UNC
Gasket contact area
14.19 in²
Type F ring
Nut factor K
0.16
Friction assumption
Min / max torque
65 / 115
ft-lb
Retainer-face stress check
Min
3,771 psi
Recommended
5,657 psi
Max
6,600 psi

Torque is set from bolt stress. Y (2,500 psi) and the 15,000 psi retainer limit are checks only, averaged over the 14.19 in² contact area.

Tightening passes — ASME PCC-1 legacy
PassTargetTorque (ft-lb)Pattern
Pass 120–30%25Star / cross pattern, evenly spaced
Pass 250–70%60Star / cross pattern, evenly spaced
Pass 3100%100Cross pattern (see sequence)
Pass 4100%100Circular, clockwise, until no further nut rotation
Pass 5Check100Check pass after ~4 hours
Bolt tightening sequence
15372648
Sequence

1 → 2 → 3 → 4 → 5 → 6 → 7 → 8

Bolts are numbered in the order they are tightened: opposite pairs first, then each half-step in turn, so the gasket is loaded evenly and the flanges stay parallel.

Notes & basis
  • Basis: new ASTM A193 B7 studs with ASTM A194 2H heavy hex nuts, hardened steel washers over isolating washers, weld-neck flanges per ASME B16.5, nut factor K = 0.16 (Copper-graphite anti-seize).
  • Dry studs: torque values increase roughly 15–25% — select “Dry / unlubricated” to recalculate.
  • Tighten per ASME PCC-1 using a cross pattern, bringing the joint up in passes and re-checking after the joint reaches operating temperature.
  • Values are calculated guidance only and do not replace joint-specific engineering.
  • Contact Protek for specialty flanges, blinds, slip-ons, lap joints, or non-standard bolting.
FAQ

Isolation gasket bolting questions

How is the torque calculated?

+

Torque follows the short-form equation T = K × F × D, where K is the nut factor, F the clamp load per bolt and D the nominal stud diameter. The clamp load comes from bolt stress: the minimum is S_min × As, the recommended is S_rec × As capped at the joint maximum, and the maximum is the lower of S_max × As and 60% of the stud yield strength × As. Gasket seating stress Y is reported as a check on the average retainer-face stress, not used to set the load.

Why do lubricated studs need less torque?

+

The nut factor K is the share of the applied torque that actually becomes clamp load. A dry thread wastes more torque on friction (K ≈ 0.20), while a fluoropolymer or moly coating lets the same clamp load be reached with roughly 15–25% less torque. Always match the torque table to the lubrication actually used on the joint.

Can I reuse studs and nuts?

+

Protek recommends new bolting for every isolation joint. Reused studs bring unknown nut factor, damaged or galled threads and prior yield, so the torque-to-load relationship is no longer reliable. If reuse is unavoidable, inspect and gauge the threads, replace any nut that has been torqued more than a few times, and use the same lubricant as the original assembly.

What tightening pattern should I use?

+

Follow ASME PCC-1: bring the joint up in passes — about 25%, then 60%, then 100% of the target torque in a star/cross pattern, a further 100% circular pass clockwise until no further nut rotation occurs, and a check pass after roughly four hours. Each row of the calculator carries its own numbered bolt sequence.