ISOLATION GASKET
TORQUE CALCULATOR
One joint, fully calculated: minimum, recommended and maximum bolt stress, the stud load each produces, the nut factor of your lubricant, and the retainer and bolt limits reported as checks.
Product & gasket style
Protek system and the gasket type in the joint.
Flange
ASME B16.5 sizes use the published bolt and gasket geometry.
8 × Ø3/4-10 UNC · Ag 14.19 in²
Bolting & lubrication
Stud grade sets yield; lubricant sets the nut factor.
Target method
What the calculated torque should achieve.
Torque is set from bolt stress. Y (2,500 psi) and the 15,000 psi retainer limit are checks only, averaged over the 14.19 in² contact area.
| Pass | Target | Torque (ft-lb) | Pattern |
|---|---|---|---|
| Pass 1 | 20–30% | 25 | Star / cross pattern, evenly spaced |
| Pass 2 | 50–70% | 60 | Star / cross pattern, evenly spaced |
| Pass 3 | 100% | 100 | Cross pattern (see sequence) |
| Pass 4 | 100% | 100 | Circular, clockwise, until no further nut rotation |
| Pass 5 | Check | 100 | Check pass after ~4 hours |
1 → 2 → 3 → 4 → 5 → 6 → 7 → 8
Bolts are numbered in the order they are tightened: opposite pairs first, then each half-step in turn, so the gasket is loaded evenly and the flanges stay parallel.
- Basis: new ASTM A193 B7 studs with ASTM A194 2H heavy hex nuts, hardened steel washers over isolating washers, weld-neck flanges per ASME B16.5, nut factor K = 0.16 (Copper-graphite anti-seize).
- Dry studs: torque values increase roughly 15–25% — select “Dry / unlubricated” to recalculate.
- Tighten per ASME PCC-1 using a cross pattern, bringing the joint up in passes and re-checking after the joint reaches operating temperature.
- Values are calculated guidance only and do not replace joint-specific engineering.
- Contact Protek for specialty flanges, blinds, slip-ons, lap joints, or non-standard bolting.
Isolation gasket bolting questions
How is the torque calculated?
+−
Torque follows the short-form equation T = K × F × D, where K is the nut factor, F the clamp load per bolt and D the nominal stud diameter. The clamp load comes from bolt stress: the minimum is S_min × As, the recommended is S_rec × As capped at the joint maximum, and the maximum is the lower of S_max × As and 60% of the stud yield strength × As. Gasket seating stress Y is reported as a check on the average retainer-face stress, not used to set the load.
Why do lubricated studs need less torque?
+−
The nut factor K is the share of the applied torque that actually becomes clamp load. A dry thread wastes more torque on friction (K ≈ 0.20), while a fluoropolymer or moly coating lets the same clamp load be reached with roughly 15–25% less torque. Always match the torque table to the lubrication actually used on the joint.
Can I reuse studs and nuts?
+−
Protek recommends new bolting for every isolation joint. Reused studs bring unknown nut factor, damaged or galled threads and prior yield, so the torque-to-load relationship is no longer reliable. If reuse is unavoidable, inspect and gauge the threads, replace any nut that has been torqued more than a few times, and use the same lubricant as the original assembly.
What tightening pattern should I use?
+−
Follow ASME PCC-1: bring the joint up in passes — about 25%, then 60%, then 100% of the target torque in a star/cross pattern, a further 100% circular pass clockwise until no further nut rotation occurs, and a check pass after roughly four hours. Each row of the calculator carries its own numbered bolt sequence.